COMPANY

 

About us

We have always been operating in the biomedical field, taking particular care in the choice of materials and machinery for the production of implant devices. The high level technology of CNC machines has been sided by our patented solutions to make them evolve further with special equipment and to allow us to fine tune the durability and reliability of our production. This has allowed us to communicate more incisively with dental professionals and to also satisfy their more specific requests for custom designed devices.

 

Continuous research

Traditional implantology is increasingly seeking only the aesthetics in implant-prosthetic devices, often at the expense of the physical-mechanical structure. On the opposite side, our primary objective is the design of flexible and durable solutions over time; the results have proven us right and the continued research drives us to constantly improve the characteristics of materials and metals and to test the modalities of application. This resulted in a highly reliable offer with aesthetic and functional effects that can support the load and the traumas of natural chewing.

 

Scientific research confirms the high quality of Oralplant

27 professionals who, through the use of Bio-Plant, Tuber-Plant, Koni-Plant and Koni-Plant M implants, have been able to evaluate, with step by step clinical protocols, the survival rate of prosthetic implants.

Periodic checks on duly informed and involved patients have allowed the drawing up of a final report on 10 years of follow-up through the MCS-01/01 research showing a success rate of 99.11% on 113 Bio-Plant and Tuber-Plant implants used, with an average bone resorption not exceeding 1.11 mm, for the Bio-Plant type and not more than 0.82 mm for the Tuber-Plant type (see publication on «Quintessenza Implantologia» 2012; 3:37-44).

More positive results are also confirmed by the new Multicentre Clinical Study MCS- 01/10 started in 2010, with Koni-Plant implants, with collars polished with OP-Lapping and Koni-Plant M implants with collars subject to Microtreatment with circular machining and “TPSS-Light”. This latest research is aimed at comparing the two types of collar and the rate of survival of the implants, that to date is 100% for the first 165 rooted implants.

 

The training of impiantology professionals

Oralplant promotes and regularly conducts theoretical and practical specialized training courses in dentistry.

A highly skilled team of professionals is available to update and support those who, among dentists, dental technicians and their assistants, wish to approach or improve their skills in implantology.

The annual conferences instead, where international industry experts and technical speakers take turns in discussing our methods and our simplified protocols, are an important opportunity for discussion, analysis and sharing of clinical case studies and of  the results obtained by the Oralplant implants.

 

What we do

 

Results are measured in well-being

Inventive technique and careful design. The origin and the development of an Oralplant implant that is reliable in time starts from here. We exclusively develop our original patents by constantly studying new surgical and prosthetic processes and by pushing research to an extreme precision, thanks to the collaboration of international specialists and to a rigorous analysis and testing process of each piece.

 

Surface treatment

The surface treatment by means of our patented TPSS (Titanium Pull Spray Superficial)
is a delicate and decisive step for the osseointegration of the Oralplant implants.
 
Thanks to this treatment we can obtain rounded and porous cavities through the surface extraction of metal parts that do not undergo molecular variations or thermal stresses.
 
The periodic checks, which patients must go through, confirm the effectiveness of our implants and the choice to treat them with a collar that is partially lapped smooth and partially TPSS treated, so that it can ensure optimum hygiene even in cases of very pointed ridges or natural bone resorption.

 

Prosthetics: Oralplant high range

Functionality and aesthetics are therefore essential characteristics for a high level implant. For this purpose, Oralplant has developed the exclusive “OP-System”, a hexagonal-tapered coupling solution that allows you to orient and block the pre-angled prosthetic abutment (10, 20, 30 and 35 degrees) in any desired position in the 360 degrees as well as a pre-angled prosthetic in 30 degrees- the only one of its kind - for the overdenture which has been developed thanks to the OP-System locking system.
 
There are other Oralplant prosthetic innovations, deriving from our experience and knowledge, such as the “Anatomic abutment OP-System” and the “Anatomical Gingival Modelling MAGO OP-System”: important new features of gingival emergency anatomy similar to that of the natural tooth, addressed to a concept of immediate, functional and aesthetic prosthetics.

Requirements of complex interventions have led our Oralplant research group to experiment and refine the “OP-Sfil” solution, featuring a removable element that allows an easy insertion and withdrawal of the prosthetic device, even with the presence of accentuated disparallelism.

This solution, neutralizing the undercut, is also used to take the dental impression with the “Coping OP-Sfil”. An interesting Solution, that has given a new change to prosthetic overdentures, is the innovation of the fixing system with the “Over-Block” damped anchor, whose main feature consists in an important resilience of overdentures to safeguard implants and roots from severe axial and side stresses. Finally, Oralplant has over 540 prefabricated abutments for high-end prosthetic solutions.